 MT9044
T1/E1/OC3 System Synchronizer Advance Information
Features
* Supports AT&T TR62411 and Bellcore GR-1244-CORE Stratum 3, Stratum 4 Enhanced and Stratum 4 timing for DS1 interfaces Supports ITU-T G.812 Type IV clocks for 1,544 kbit/s interfaces and 2,048 kbit/s interfaces Supports ETSI ETS 300 011, TBR 4, TBR 12 and TBR 13 timing for E1 interfaces Selectable 1.544MHz, 2.048MHz or 8kHz input reference signals Provides C1.5, C2, C3, C4, C6, C8, C16, and C19 (STS-3/OC3 clock divided by 8) output clock signals Provides 5 different styles of 8 KHz framing pulses Holdover frequency accuracy of 0.05 PPM Holdover indication Attenuates wander from 1.9Hz Provides Time Interval Error (TIE) correction Accepts reference inputs from two independent sources JTAG Boundary Scan
DS5058 ISSUE 3 September 1999
Ordering Information MT9044AP 44 Pin PLCC MT9044AL 44 Pin MQFP -40 to +85 C
* * * *
Description
The MT9044 T1/E1/OC3 System Synchronizer contains a digital phase-locked loop (DPLL), which provides timing and synchronization signals for multitrunk T1 and E1 primary rate transmission links and STS-3/0C3 links. The MT9044 generates ST-BUS clock and framing signals that are phase locked to either a 2.048MHz, 1.544MHz, or 8kHz input reference. The MT9044 is compliant with AT&T TR62411 and Bellcore GR-1244-CORE Stratum 3, Stratum 4 Enhanced, and Stratum 4; and ETSI ETS 300 011. It will meet the jitter/wander tolerance, jitter/wander transfer, intrinsic jitter/wander, frequency accuracy, capture range, phase change slope, holdover frequency and MTIE requirements for these specifications.
* * * * * * *
Applications
* * Synchronization and timing control for multitrunk T1,E1 and STS-3/OC3 systems ST-BUS clock and frame pulse sources
OSCi OSCo TCLR
VDD
VSS
Master Clock TCK TDI TMS TRST TDO PRI SEC IEEE 1149.1a TIE Corrector Circuit
Virtual Reference DPLL Output Interface Circuit
Reference Select MUX Reference Select
Selected Reference
State Select Input Impairment Monitor
TIE Corrector Enable
State Select
C19o C1.5o C3o C2o C4o C6o C8o C16o F0o F8o F16o RSP TSP
Feedback RSEL LOS1 LOS2 Automatic/Manual Control State Machine Guard Time Circuit Frequency Select MUX APLL ACKo
ACKi
MS1
MS2
RST HOLDOVER
GTo
GTi
FS1
FS2
Figure 1 - Functional Block Diagram
1
MT9044
Advance Information
PRI SEC TRST TCLR TCK VSS TMS RST TDI FS1 FS2
6 5 4 3 2 1 44 43 42 41 40
PRI SEC TRST TCLR TCLK VSS TMS RST TDI FS1 FS2
44 43 42 41 40 39 38 37 36 35 34 39 38 37 36 35 34 33 32 31 30 29
VDD OSCo OSCi VSS F16o RSP F0o TSP F8o C1.5o AVDD
7 8 9 10 11 12 13 14 15 16 17
MT9044
TEST RSEL MS1 MS2 TDO LOS1 LOS2 GTo VSS GTi HOLDOVER
VDD OSCo OSCi VSS F16o RSP F0o TSP F8o C1.5o AVDD
1 2 3 4 5 6 7 8 9 10 11
MT9044AL
33 32 31 30 29 28 27 26 25 24 23
TEST RSEL MS1 MS2 TDO LOS1 LOS2 GTo VSS GTi HOLDOVER
18 19 20 21 22 23 24 25 26 27 28
12 13 14 15 16 17 18 19 20 21 22
C3o C2o C4o C19o
ACKi VSS ACKo C8o C16o C6o VDD
Figure 2 - Pin Connections
Pin Description
Pin # Pin # PLCC MQFP 1,10, 39,4,17 23,31 ,25 2 3 40 41 Name VSS TCK TCLR Ground. 0 Volts. Test Clock (TTL Input): Provides the clock to the JTAG test logic. This pin is internally pulled up to VDD. TIE Circuit Reset (TTL Input): A logic low at this input resets the Time Interval Error (TIE) correction circuit resulting in a re-alignment of input phase with output phase as shown in Figure 19. The TCLR pin should be held low for a minimum of 300ns. This pin is internally pulled down to VSS. Test Reset (TTL Input): Asynchronously initializes the JTAG TAP controller by putting it in the Test-Logic-Reset state. This pin is internally pulled down to VSS. Secondary Reference (TTL Input). This is one of two (PRI & SEC) input reference sources (falling edge) used for synchronization. One of three possible frequencies (8kHz, 1.544MHzMHz, or 2.048MHz) may be used. The selection of the input reference is based upon the MS1, MS2, LOS1, LOS2, RSEL, and GTi control inputs (Automatic or Manual). This pin is internally pulled up to VDD. Primary Reference (TTL Input). See pin description for SEC. This pin is internally pulled up to VDD. Positive Supply Voltage. +5VDC nominal. Oscillator Master Clock (CMOS Output). For crystal operation, a 20MHz crystal is connected from this pin to OSCi, see Figure 10. For clock oscillator operation, this pin is left unconnected, see Figure 9. Oscillator Master Clock (CMOS Input). For crystal operation, a 20MHz crystal is connected from this pin to OSCo, see Figure 10. For clock oscillator operation, this pin is connected to a clock source, see Figure 9. Frame Pulse ST-BUS 8.192 Mb/s (CMOS Output). This is an 8kHz 61ns active low framing pulse, which marks the beginning of an ST-BUS frame. This is typically used for ST-BUS operation at 8.192 Mb/s. See Figure 20. Description
4 5
42 43
TRST SEC
6 7,28 8
44 1,22 2
PRI VDD OSCo
9
3
OSCi
11
5
F16o
2
C3o C2o C4o C19o ACKi VSS ACKo C8o C16o C6o VDD
Advance Information
Pin Description (continued)
Pin # Pin # PLCC MQFP 12 6 Name RSP Description
MT9044
Receive Sync Pulse (CMOS Output). This is an 8kHz 488ns active high framing pulse, which marks the end of an ST-BUS frame. This is typically used for connection to the Siemens MUNICH-32 device. See Figure 21. Frame Pulse ST-BUS 2.048Mb/s (CMOS Output). This is an 8kHz 244ns active low framing pulse, which marks the beginning of an ST-BUS frame. This is typically used for ST-BUS operation at 2.048Mb/s and 4.096Mb/s. See Figure 20. Transmit Sync Pulse (CMOS Output). This is an 8kHz 488ns active high framing pulse, which marks the beginning of an ST-BUS frame. This is typically used for connection to the Siemens MUNICH-32 device. See Figure 21. Frame Pulse (CMOS Output). This is an 8kHz 122ns active high framing pulse, which marks the beginning of a frame. See Figure 20. Clock 1.544MHz (CMOS Output). This output is used in T1 applications. Analog Vdd. +5VDC nominal. Clock 3.088MHz (CMOS Output). This output is used in T1 applications. Clock 2.048MHz (CMOS Output). This output is used for ST-BUS operation at 2.048Mb/s. Clock 4.096MHz (CMOS Output). This output is used for ST-BUS operation at 2.048Mb/s and 4.096Mb/s. Clock 19.44MHz (CMOS Output). This output is used in OC3/STS3 applications. Analog PLL Clock Input (CMOS Input). This input clock is a reference for an internal analog PLL. This pin is internally pulled down to VSS. Analog PLL Clock Output (CMOS Output). This output clock is generated by the internal analog PLL. Clock 8.192MHz (CMOS Output). This output is used for ST-BUS operation at 8.192Mb/s. Clock 16.384MHz (CMOS Output). This output is used for ST-BUS operation with a 16.384MHz clock. Clock 6.312 Mhz (CMOS Output). This output is used for DS2 applications.
13
7
F0o
14
8
TSP
15 16 17 18 19 20 21 22 24 25 26 27 29 30
9 10 11 12 13 14 15 16 18 19 20 21 23 24
F8o C1.5o AVdd C3o C2o C4o C19o ACKi ACKo C8o C16o C6o
HOLDOVER Holdover (CMOS Output). This output goes to a logic high whenever the digital PLL goes into holdover mode. GTi Guard Time (Schmitt Input). This input is used by the MT9044 state machine in both Manual and Automatic modes. The signal at this pin affects the state changes between Primary Holdover Mode and Primary Normal Mode, and Primary Holdover Mode and Secondary Normal Mode. The logic level at this input is gated in by the rising edge of F8o. See Tables 4 and 5. Guard Time (CMOS Output). The LOS1 input is gated by the rising edge of F8o, buffered and output on GTo. This pin is typically used to drive the GTi input through an RC circuit. Secondary Reference Loss (TTL Input). This input is normally connected to the loss of signal (LOS) output signal of a Line Interface Unit (LIU). When high, the SEC reference signal is lost or invalid. LOS2, along with the LOS1 and GTi inputs control the MT9044 state machine when operating in Automatic Control. The logic level at this input is gated in by the rising edge of F8o. This pin is internally pulled down to VSS.
32
26
GTo
33
27
LOS2
3
MT9044
Pin Description (continued)
Pin # Pin # PLCC MQFP 34 28 Name LOS1 Description
Advance Information
Primary Reference Loss (TTL Input). Typically, external equipment applies a logic high to this input when the PRI reference signal is lost or invalid. The logic level at this input is gated in by the rising edge of F8o. See LOS2 description. This pin is internally pulled down to VSS. Test Serial Data Out (TTL Output). JTAG serial data is output on this pin on the falling edge of TCK. This pin is held in high impedance state when JTAG scan is not enable. Mode/Control Select 2 (TTL Input). This input, in conjunction with MS1, determines the device's mode (Automatic or Manual) and state (Normal, Holdover or Freerun) of operation. The logic level at this input is gated in by the rising edge of F8o. See Table 3. Mode/Control Select 1 (TTL Input). The logic level at this input is gated in by the rising edge of F8o. See pin description for MS2. This pin is internally pulled down to VSS. Reference Source Select (TTL Input). In Manual Control, a logic low selects the PRI (primary) reference source as the input reference signal and a logic high selects the SEC (secondary) input. In Automatic Control, this pin must be at logic low. The logic level at this input is gated in by the rising edge of F8o. See Table 2. This pin is internally pulled down to VSS. Test (TTL Input). This input is normally tied low. When pulled high, it enables internal test modes. This pin is internally pulled down to VSS. Frequency Select 2 (TTL Input). This input, in conjunction with FS1, selects which of three possible frequencies (8kHz, 1.544MHz, or 2.048MHz) may be input to the PRI and SEC inputs. See Table 1. Frequency Select 1 (TTL Input). See pin description for FS2. Test Serial Data In (TTL Input). JTAG serial test instructions and data are shifted in on this pin. This pin is internally pulled up to VDD. Reset (Schmitt Input). A logic low at this input resets the MT9044. To ensure proper operation, the device must be reset after changes to the method of control, reference signal frequency changes and power-up. The RST pin should be held low for a minimum of 300ns. While the RST pin is low, all frame and clock outputs are at logic high. Following a reset, the input reference source and output clocks and frame pulses are phase aligned as shown in Figure 19. Test Mode Select (TTL Input). JTAG signal that controls the state transitions of the TAP controller. This pin is internally pulled up to VDD.
35
29
TDO
36
30
MS2
37
31
MS1
38
32
RSEL
39 40
33 34
TEST FS2
41 42 43
35 36 37
FS1 TDI RST
44
38
TMS
4
Advance Information
Functional Description
The MT9044 is a Multitrunk System Synchronizer, providing timing (clock) and synchronization (frame) signals to interface circuits for T1 and E1 Primary Rate Digital Transmission links. Figure 1 shows the functional block diagram which is described in the following sections. Reference Select MUX Circuit The MT9044 accepts two simultaneous reference input signals and operates on their falling edges. Either the primary reference (PRI) signal or the secondary reference (SEC) signal can be selected as input to the TIE Corrector Circuit. The selection is based on the Control, Mode and Reference Selection of the device. See Tables 1, 4 and 5. Frequency Select MUX Circuit The MT9044 operates with one of three possible input reference frequencies (8kHz, 1.544MHz or 2.048MHz). The frequency select inputs (FS1 and FS2) determine which of the three frequencies may be used at the reference inputs (PRI and SEC). Both inputs must have the same frequency applied to them. A reset (RST) must be performed after every frequency select input change. Operation with FS1 and FS2 both at logic low is reserved and must not be used. See Table 1. FS2 0 0 1 1 FS1 0 1 0 1
MT9044
Input Frequency Reserved 8kHz 1.544MHz 2.048MHz
Table 1 - Input Frequency Selection Time Interval Error (TIE) Corrector Circuit The TIE corrector circuit, when enabled, prevents a step change in phase on the input reference signals (PRI or SEC) from causing a step change in phase at the input of the DPLL block of Figure 1. During reference input rearrangement, such as during a switch from the primary reference (PRI) to the secondary reference (SEC), a step change in phase on the output signals will occur. A phase step at the input of the DPLL will lead to unacceptable phase changes in the output signal. As shown in Figure 3, the TIE Corrector Circuit receives one of the two reference (PRI or SEC) signals, passes the signal through a programmable delay line, and uses this delayed signal as an internal virtual reference, which is input to the DPLL. Therefore, the virtual reference is a delayed version of the selected reference. During a switch, from one reference to the other, the State Machine first changes the mode of the device
TCLR Resets Delay Control Circuit Control Signal
Delay Value
PRI or SEC from Reference Select Mux
Programmable Delay Circuit
Virtual Reference to DPLL Compare Circuit
TIE Corrector Enable from State Machine
Feedback Signal from Frequency Select MUX
Figure 3 - TIE Corrector Circuit
5
MT9044
from Normal to Holdover. In Holdover Mode, the DPLL no longer uses the virtual reference signal, but generates an accurate clock signal using storage techniques. The Compare Circuit then measures the phase delay between the current phase (feedback signal) and the phase of the new reference signal. This delay value is passed to the Programmable Delay Circuit (See Figure 3). The new virtual reference signal is now at the same phase position as the previous reference signal would have been if the reference switch had not taken place. The State Machine then returns the device to Normal Mode. The DPLL now uses the new virtual reference signal, and since no phase step took place at the input of the DPLL, no phase step occurs at the output of the DPLL. In other words, reference switching will not create a phase change at the input of the DPLL, or at the output of the DPLL. Since internal delay circuitry maintains the alignment between the old virtual reference and the new virtual reference, a phase error may exist between the selected input reference signal and the output signal of the DPLL. This phase error is a function of the difference in phase between the two input reference signals during reference rearrangements. Each time a reference switch is made, the delay between input signal and output signal will change. The value of this delay is the accumulation of the error measured during each reference switch. The programmable delay circuit can be zeroed by applying a logic low pulse to the TIE Circuit Reset (TCLR) pin. A minimum reset pulse width is 300ns. This results in a phase alignment between the input reference signal and the output signal as shown in Figure 20. The speed of the phase alignment correction is limited to 5ns per 125us, and convergence is in the direction of least phase travel. The state diagrams of Figure 7 and 8 indicate the state changes that activate the TIE Corrector Circuit.
Advance Information
Digital Phase Lock Loop (DPLL) As shown in Figure 4, the DPLL of the MT9044 consists of a Phase Detector, Limiter, Loop Filter, Digitally Controlled Oscillator, and a Control Circuit. Phase Detector - the Phase Detector compares the virtual reference signal from the TIE Corrector circuit with the feedback signal from the Frequency Select MUX circuit, and provides an error signal corresponding to the phase difference between the two. This error signal is passed to the Limiter circuit. The Frequency Select MUX allows the proper feedback signal to be externally selected (e.g., 8kHz, 1.544MHz or 2.048MHz). Limiter - the Limiter receives the error signal from the Phase Detector and ensures that the DPLL responds to all input transient conditions with a maximum output phase slope of 5ns per 125us. This is well within the maximum phase slope of 7.6ns per 125us or 81ns per 1.326ms specified by AT&T TR62411, and Bellcore GR-1244-CORE. Loop Filter - the Loop Filter is similar to a first order low pass filter with a 1.9 Hz cutoff frequency for all three reference frequency selections (8kHz, 1.544MHz or 2.048MHz). This filter ensures that the jitter transfer requirements in ETS 300 011 and AT&T TR62411 are met. Control Circuit - the Control Circuit uses status and control information from the State Machine and the Input Impairment Circuit to set the mode of the DPLL. The three possible modes are Normal, Holdover and Freerun. Digitally Controlled Oscillator (DCO) - the DCO receives the limited and filtered signal from the Loop FIlter, and based on its value, generates a corresponding digital output signal. The synchronization method of the DCO is dependent on the state of the MT9044.
Virtual Reference from TIE Corrector
Phase Detector
Limiter
Loop Filter
Digitally Controlled Oscillator
DPLL Reference to Output Interface Circuit
Feedback Signal from Frequency Select MUX
State Select from Input Impairment Monitor
Control Circuit
State Select from State Machine
Figure 4 - DPLL Block Diagram
6
Advance Information
In Normal Mode, the DCO provides an output signal which is frequency and phase locked to the selected input reference signal.
12MHz
MT9044
C1.5o C3o
T1 Divider
In Holdover Mode, the DCO is free running at a frequency equal to the last (less 30ms to 60ms) frequency the DCO was generating while in Normal Mode. In Freerun Mode, the DCO is free running with an accuracy equal to the accuracy of the OSCi 20MHz source. Output Interface Circuit The output of the DCO (DPLL) is used by the Output Interface Circuit to provide the output signals shown in Figure 5. The Output Interface Circuit uses four Tapped Delay Lines followed by a T1 Divider Circuit , an E1 Divider Circuit, a DS2 Divider Circuit and an analog PLL to generate the required output signals. Four tapped delay lines are used to generate a 16.384MHz, 12.352MHz, 12.624MHz and 19.44 MHz signals. The E1 Divider Circuit uses the 16.384MHz signal to generate four clock outputs and three frame pulse outputs. The C8o, C4o and C2o clocks are generated by simply dividing the C16o clock by two, four and eight respectively. These outputs have a nominal 50% duty cycle. The T1 Divider Circuit uses the 12.384MHz signal to generate two clock outputs. C1.5o and C3o are generated by dividing the internal C12 clock by four and eight respectively. These outputs have a nominal 50% duty cycle. The DS2 Divider Circuit uses the 12.624 MHz signal to generate the clock output C6o. This output has a nominal 50% duty cycle.
Tapped Delay Line
E1 Divider From DPLL Tapped Delay Line 16MHz
C2o C4o C8o C16o F0o F8o F16o
Tapped Delay Line
12MHz
DS2 Divider
C6o
Tapped Delay Line
19MHz
C19o
Analog PLL ACKi
ACKo
Figure 5 - Output Interface Circuit Block Diagram The frame pulse outputs (F0o, F8o, F16o, TSP, RSP) are generated directly from the C16 clock. The T1 and E1 signals are generated from a common DPLL signal. Consequently, the clock outputs C1.5o, C3o, C2o, C4o, C8o, C16o, F0o, F16o and C6o are locked to one another for all operating states, and are also locked to the selected input reference in Normal Mode. See Figures 20 and 21. All frame pulse and clock outputs have limited driving capability, and should be buffered when driving high capacitance (e.g. 30pF) loads. Analog Phase Lock Loop (APLL) The analog PLL is intended to be used to achieve a 50% duty cycle output clock. Connecting C19o to ACKi will generate a phase locked 19.44 MHz ACKo output with a nominal 50% duty cycle. The analog PLL has an intrinsic jitter of less than 0.01 U.I. In order to achieve this low jitter level a separate pin is provided to power (AVdd) the analog PLL.
7
MT9044
Input Impairment Monitor This circuit monitors the input signal to the DPLL and automatically enables the Holdover Mode (Auto-Holdover) when the frequency of the incoming signal is outside the auto-holdover capture range (See AC Electrical Characteristics - Performance). This includes a complete loss of incoming signal, or a large frequency shift in the incoming signal. When the incoming signal returns to normal, the DPLL is returned to Normal Mode with the output signal locked to the input signal. The holdover output signal is based on the incoming signal 30ms minimum to 60ms prior to entering the Holdover Mode. The amount of phase drift while in holdover is negligible because the Holdover Mode is very accurate (e.g. 0.05ppm). The the Auto-Holdover circuit does not use TIE correction. Consequently, the phase delay between the input and output after switching back to Normal Mode is preserved (is the same as just prior to the switch to Auto-Holdover). Automatic/Manual Control State Machine The Automatic/Manual Control State Machine allows the MT9044 to be controlled automatically (i.e. LOS1, LOS2 and GTi signals) or controlled manually (i.e. MS1, MS2, GTi and RSEL signals). With manual control a single mode of operation (i.e. Normal, Holdover and Freerun) is selected. Under automatic control the state of the LOS1, LOS2 and GTi signals determines the sequence of modes that the MT9044 will follow. As shown in Figure 1, this state machine controls the Reference Select MUX, the TIE Corrector Circuit, the DPLL and the Guard Time Circuit. Control is based on the logic levels at the control inputs LOS1, LOS2, RSEL, MS1, MS2 and GTi of the Guard Time Circuit (See Figure 6). All state machine changes occur synchronously on the rising edge of F8o. See the Controls and Modes of Operation section for full details on Automatic Control and Manual Control.
To Reference Select MUX To TIE Corrector Enable To DPLL State Select
Advance Information
Guard Time Circuit The GTi pin is used by the Automatic/Manual Control State Machine in the MT9044 under either Manual or Automatic control. The logic level at the GTi pin performs two functions, it enables and disables the TIE Corrector Circuit (Manual and Automatic), and it selects which mode change takes place (Automatic only). See the Applications - Guard Time section. For both Manual and Automatic control, when switching from Primary Holdover to Primary Normal, the TIE Corrector Circuit is enabled when GTi=1, and disabled when GTi=0. Under Automatic control and in Primary Normal Mode, two state changes are possible (not counting Auto-Holdover). These are state changes to Primary Holdover or to Secondary Normal. The logic level at the GTi pin determines which state change occurs. When GTi=0, the state change is to Primary Holdover. When GTi=1, the state change is to Secondary Normal. Master Clock The MT9044 can use either a clock or crystal as the master timing source. For recommended master timing circuits, see the Applications - Master Clock section.
Control and Modes of Operation
The MT9044 can operate either in Manual or Automatic Control. Each control method has three possible modes of operation, Normal, Holdover and Freerun. As shown in Table 3, Mode/Control Select pins MS2 and MS1 select the mode and method of control. Control MANUAL RSEL 0 1 AUTO 0 1 Input Reference PRI SEC State Machine Control Reserved
RSEL LOS1 LOS2
Automatic/Manual Control State Machine
To and From Guard Time Circuit
Table 2 - Input Reference Selection
MS1
MS2
Figure 6 - Automatic/Manual Control State Machine Block Diagram
8
Advance Information
Normal Mode MS2 0 0 1 1 MS1 0 1 0 1 Control MANUAL MANUAL MANUAL AUTO Mode NORMAL HOLDOVER FREERUN State Machine Control
MT9044
Normal Mode is typically used when a slave clock source, synchronized to the network is required. In Normal Mode, the MT9044 provides timing (C1.5o, C2o, C3o, C4o, C8o, C16o, and C19) and frame synchronization (F0o, F8o, F16o, RSP, TSP) signals, which are synchronized to one of two reference inputs (PRI or SEC). The input reference signal may have a nominal frequency of 8kHz, 1.544MHz or 2.048MHz. From a reset condition, the MT9044 will take up to 25 seconds for the output signal to be phase locked to the selected reference. The selection of input references is control dependent as shown in State Tables 4 and 5. The reference frequencies are selected by the frequency control pins FS2 and FS1 as shown in Table 1. Holdover Mode Holdover Mode is typically used for short durations (e.g. 2 seconds) while network synchronization is temporarily disrupted. In Holdover Mode, the MT9044 provides timing and synchronization signals, which are not locked to an external reference signal, but are based on storage techniques. The storage value is determined while the device is in Normal Mode and locked to an external reference signal. When in Normal Mode, and locked to the input reference signal, a numerical value corresponding to the MT9044 output frequency is stored alternately in two memory locations every 30ms. When the device is switched into Holdover Mode, the value in memory from between 30ms and 60ms is used to set the output frequency of the device. The frequency accuracy of Holdover Mode is 0.05ppm, which translates to a worst case 35 frame (125us) slips in 24 hours. This meets the Bellcore GR-1244-CORE Stratum 3 requirement of 0.37ppm (255 frame slips per 24 hours). Two factors affect the accuracy of Holdover Mode. One is drift on the Master Clock while in Holdover Mode, drift on the Master Clock directly affects the Holdover Mode accuracy. Note that the absolute Master Clock (OSCi) accuracy does not affect Holdover accuracy, only the change in OSCi accuracy while in Holdover. For example, a 32ppm
9
Table 3 - Operating Modes and States Manual Control Manual Control should be used when either very simple MT9044 control is required, or when complex control is required which is not accommodated by Automatic Control. For example, very simple control could include operation in a system which only requires Normal Mode with reference switching using only a single input stimulus (RSEL). Very simple control would require no external circuitry. Complex control could include a system which requires state changes between Normal, Holdover and Freerun Modes based on numerous input stimuli. Complex control would require external circuitry, typically a microcontroller. Under Manual Control, one of the three modes is selected by mode/control select pins MS2 and MS1. The active reference input (PRI or SEC) is selected by the RSEL pin as shown in Table 2. Refer to Table 4 and Figure 7 for details of the state change sequences. Automatic Control Automatic Control should be used when simple MT9044 control is required, which is more complex than the very simple control provide by Manual Control with no external circuitry, but not as complex as Manual Control with a microcontroller. For example, simple control could include operation in a system which can be accommodated by the Automatic Control State Diagram shown in Figure 8. Automatic Control is also selected by mode/control pins MS2 and MS1. However, the mode and active reference source is selected automatically by the internal Automatic State Machine (See Figure 6). The mode and reference changes are based on the logic levels on the LOS1, LOS2 and GTi control pins. Refer to Table 5 and Figure 8 for details of the state change sequences.
MT9044
master clock may have a temperature coefficient of 0.1ppm per degree C. So a 10 degree change in temperature, while the MT9044 is in Holdover Mode may result in an additional offset (over the 0.05ppm) in frequency accuracy of 1ppm, which is much greater than the 0.05ppm of the MT9044. The other factor affecting accuracy is large jitter on the reference input prior (30ms to 60ms) to the mode switch. For instance, jitter of 7.5UI at 700Hz may reduce the Holdover Mode accuracy from 0.05ppm to 0.10ppm. Freerun Mode Freerun Mode is typically used when a master clock source is required, or immediately following system power-up before network synchronization is achieved. In Freerun Mode, the MT9044 provides timing synchronization signals which are based on master clock frequency (OSCi) only, and are synchronized to the reference signals (PRI SEC). and the not and
Advance Information
The accuracy of the output clock is equal to the accuracy of the master clock (OSCi). So if a 32ppm output clock is required, the master clock must also be 32ppm. See Applications - Crystal and Clock Oscillator sections.
10
Advance Information
Description Input Controls MS2 0 0 0 0 0 1 MS1 0 0 0 1 1 0 RSEL 0 0 1 0 1 X GTi 0 1 X X X X Freerun S0 S1 S1 S2 / / Normal (PRI) S1 S2 MTIE S1H S2H S0 State Normal (SEC) S2 S1 MTIE S1 MTIE / S2H S0 Holdover (PRI) S1H S1 S1 MTIE S2 MTIE / S0
MT9044
Holdover (SEC) S2H S1 MTIE S1 MTIE S2 MTIE / S0
Legend: No Change / Not Valid MTIE State change occurs with TIE Corrector Circuit Refer to Manual Control State Diagram for state changes to and from Auto-Holdover State
Table 4 - Manual Control State Table
S0 Freerun (10X)
S1 Normal Primary (000)
{A}
S1A Auto-Holdover Primary (000)
S2A Auto-Holdover Secondary (001)
{A}
S2 Normal Secondary (001)
(GTi=0) (GTi=1)
S1H Holdover Primary (010)
S2H Holdover Secondary (011)
NOTES: (XXX) MS2 MS1 RSEL {A} Invalid Reference Signal Movement to Normal State from any state requires a valid input signal
Phase Re-Alignment Phase Continuity Maintained (without TIE Corrector Circuit) Phase Continuity Maintained (with TIE Corrector Circuit)
Figure 7 - Manual Control State Diagram
11
MT9044
Description Input Controls LOS2 1 X X 0 0 1 LOS1 1 0 0 1 1 1 GTi X 0 1 0 1 X RST 0 to 1 1 1 1 1 1 Freerun S0 S1 S1 S1 S2 Normal (PRI) S1 S0 S1H S2 MTIE S1H State Normal (SEC) S2 S0 S1 MTIE S1 MTIE S2H
Advance Information
Holdover (PRI) S1H S0 S1 S1 MTIE S2 MTIE -
Holdover (SEC) S2H S0 S1 MTIE S1 MTIE S2 MTIE S2 MTIE -
Legend: No Change MTIE State change occurs with TIE Corrector Circuit Refer to Automatic Control State Diagram for state changes to and from Auto-Holdover State
Table 5 - Automatic Control (MS1=MS2=1, RSEL=0) State Table
(11X) (11X) RST=1 Reset (X0X) S0 Freerun
(01X)
(X0X) (X0X) S1 Normal Primary (X0X) {A} S1A Auto-Holdover Primary
(01X) (01X) (01X) S2A Auto-Holdover Secondary {A} S2 Normal Secondary
(X0X) (011) (010 or 11X) (X00) (X01) S1H Holdover Primary S2H Holdover Secondary (11X) (X0X) (011) (01X)
(010 or 11X) NOTES: (XXX) LOS2 LOS1 GTi {A} Invalid Reference Signal Movement to Normal State from any state requires a valid input signal
(11X)
Phase Re-Alignment Phase Continuity Maintained (without TIE Corrector Circuit) Phase Continuity Maintained (with TIE Corrector Circuit)
Figure 8 - Automatic Control State Diagram
12
Advance Information
MT9044 Measures of Performance
The following are some synchronizer performance indicators and their corresponding definitions. Intrinsic Jitter Intrinsic jitter is the jitter produced by the synchronizing circuit and is measured at its output. It is measured by applying a reference signal with no jitter to the input of the device, and measuring its output jitter. Intrinsic jitter may also be measured when the device is in a non-synchronizing mode, such as free running or holdover, by measuring the output jitter of the device. Intrinsic jitter is usually measured with various bandlimiting filters depending on the applicable standards. Jitter Tolerance Jitter tolerance is a measure of the ability of a PLL to operate properly (i.e., remain in lock and or regain lock in the presence of large jitter magnitudes at various jitter frequencies) when jitter is applied to its reference. The applied jitter magnitude and jitter frequency depends on the applicable standards. Jitter Transfer Jitter transfer or jitter attenuation refers to the magnitude of jitter at the output of a device for a given amount of jitter at the input of the device. Input jitter is applied at various amplitudes and frequencies, and output jitter is measured with various filters depending on the applicable standards. For the MT9044, two internal elements determine the jitter attenuation. This includes the internal 1.9Hz low pass loop filter and the phase slope limiter. The phase slope limiter limits the output phase slope to 5ns/125us. Therefore, if the input signal exceeds this rate, such as for very large amplitude low frequency input jitter, the maximum output phase slope will be limited (i.e. attenuated) to 5ns/125us. The MT9044 has thirteen outputs with three possible input frequencies for a total of 39 possible jitter transfer functions. However, the data sheet section on AC Electrical Characteristics - Jitter Transfer specifies transfer values for only three cases, 8kHz to 8kHz, 1.544MHz to 1.544MHz and 2.048MHz to 2.048MHz. Since all outputs are derived from the
MT9044
same signal, these transfer values apply to all outputs. It should be noted that 1UI at 1.544MHz is 644ns, which is not equal to 1UI at 2.048MHz, which is 488ns. Consequently, a transfer value using different input and output frequencies must be calculated in common units (e.g. seconds) as shown in the following example.
What is the T1 and E1 output jitter when the T1 input jitter is 20UI (T1 UI Units) and the T1 to T1 jitter attenuation is 18dB?
- A ----- 20
OutputT 1 = InputT 1 x10 OutputT 1 = 20 x10 - 18 ------- 20
= 2.5UI ( T 1 )
( 1UIT 1 ) OutputE1 = OutputT 1 x --------------------( 1UIE1 ) ( 644ns ) OutputE1 = OutputT 1 x ------------------- = 3.3UI ( T 1 ) ( 488ns ) Using the above method, the jitter attenuation can be calculated for all combinations of inputs and outputs based on the three jitter transfer functions provided. Note that the resulting jitter transfer functions for all combinations of inputs (8kHz, 1.544MHz, 2.048MHz) and outputs (8kHz, 1.544MHz, 2.048MHz, 4.096MHz, 8.192MHz, 16.384MHz) for a given input signal (jitter frequency and jitter amplitude) are the same. Since intrinsic jitter is always present, jitter attenuation will appear to be lower for small input jitter signals than for large ones. Consequently, accurate jitter transfer function measurements are usually made with large input jitter signals (e.g. 75% of the specified maximum jitter tolerance). Frequency Accuracy Frequency accuracy is defined as the absolute tolerance of an output clock signal when it is not locked to an external reference, but is operating in a free running mode. For the MT9044, the Freerun accuracy is equal to the Master Clock (OSCi) accuracy. Holdover Accuracy Holdover accuracy is defined as the absolute tolerance of an output clock signal, when it is not
13
MT9044
locked to an external reference signal, but is operating using storage techniques. For the MT9044, the storage value is determined while the device is in Normal Mode and locked to an external reference signal. The absolute Master Clock (OSCi) accuracy of the MT9044 does not affect Holdover accuracy, but the change in OSCi accuracy while in Holdover Mode does. Capture Range Also referred to as pull-in range. This is the input frequency range over which the synchronizer must be able to pull into synchronization. The MT9044 capture range is equal to 230ppm minus the accuracy of the master clock (OSCi). For example, a 32ppm master clock results in a capture range of 198ppm. Lock Range This is the input frequency range over which the synchronizer must be able to maintain synchronization. The lock range is equal to the capture range for the MT9044. Phase Slope Phase slope is measured in seconds per second and is the rate at which a given signal changes phase with respect to an ideal signal. The given signal is typically the output signal. The ideal signal is of constant frequency and is nominally equal to the value of the final output signal or final input signal. Time Interval Error (TIE) TIE is the time delay between a given timing signal and an ideal timing signal. Maximum Time Interval Error (MTIE) MTIE is the maximum peak to peak delay between a given timing signal and an ideal timing signal within a particular observation period. MTIE ( S ) = TIEmax ( t ) - TIEmin ( t )
Advance Information
end of a particular observation period. Usually, the given timing signal and the ideal timing signal are of the same frequency. Phase continuity applies to the output of the synchronizer after a signal disturbance due to a reference switch or a mode change. The observation period is usually the time from the disturbance, to just after the synchronizer has settled to a steady state. In the case of the MT9044, the output signal phase continuity is maintained to within 5ns at the instance (over one frame) of all reference switches and all mode changes. The total phase shift, depending on the switch or type of mode change, may accumulate up to 200ns over many frames. The rate of change of the 200ns phase shift is limited to a maximum phase slope of approximately 5ns/125us. This meets the maximum phase slope requirement of Bellcore GR-1244-CORE (81ns/ 1.326ms). Phase Lock Time This is the time it takes the synchronizer to phase lock to the input signal. Phase lock occurs when the input signal and output signal are not changing in phase with respect to each other (not including jitter). Lock time is very difficult to determine because it is affected by many factors which include: i) initial input to output phase difference ii) initial input to output frequency difference iii) synchronizer loop filter iv) synchronizer limiter Although a short lock time is desirable, it is not always possible to achieve due to other synchronizer requirements. For instance, better jitter transfer performance is achieved with a lower frequency loop filter which increases lock time. And better (smaller) phase slope performance (limiter) results in longer lock times. The MT9044 loop filter and limiter were optimized to meet the AT&T TR62411 jitter transfer and phase slope requirements. Consequently, phase lock time, which is not a standards requirement, may be longer than in other applications. See AC Electrical Characteristics Performance for maximum phase lock time.
Phase Continuity Phase continuity is the phase difference between a given timing signal and an ideal timing signal at the
14
Advance Information
MT9044 and Network Specifications
The MT9044 fully meets all applicable PLL requirements (intrinsic jitter/wander, jitter/wander tolerance, jitter/wander transfer, frequency accuracy, frequency holdover accuracy, capture range, phase change slope and MTIE during reference rearrangement) for the following specifications. 1. Bellcore GR-1244-CORE June 1995 for Stratum 3, Stratum 4 Enhanced and Stratum 4 2. AT&T TR62411 (DS1) December 1990 for Stratum 3, Stratum 4 Enhanced and Stratum 4 3. ANSI T1.101 (DS1) February 1994 for Stratum 3, Stratum 4 Enhanced and Stratum 4 4. ETSI 300 011 (E1) April 1992 for Single Access and Multi Access 5. TBR 4 November 1995 6. TBR 12 December 1993 7. TBR 13 January 1996 8. ITU-T I.431 March 1993 9. ITU-T G.812 June 1998 for type IV clocks for 1,544 kbit/s interfaces and 2,048 kbit/s interfaces
MT9044
Applications
This section contains MT9044 application specific details for clock and crystal operation, guard time usage, reset operation, power supply decoupling, Manual Control operation and Automatic Control operation. Master Clock The MT9044 can use either a clock or crystal as the master timing source. In Freerun Mode, the frequency tolerance at the clock outputs is identical to the frequency tolerance of the source at the OSCi pin. For applications not requiring an accurate Freerun Mode, tolerance of the master timing source may be 100ppm. For applications requiring an accurate Freerun Mode, such as Bellcore GR-1244-CORE, the tolerance of the master timing source must Be no greater than 32ppm. Another consideration in determining the accuracy of the master timing source is the desired capture range. The sum of the accuracy of the master timing source and the capture range of the MT9044 will always equal 230ppm. For example, if the master timing source is 100ppm, then the capture range will be 130ppm. Clock Oscillator - when selecting a Clock Oscillator, numerous parameters must be considered. This includes absolute frequency, frequency change over temperature, output rise and fall times, output levels and duty cycle. See AC Electrical Characteristics.
MT9044 OSCi +5V
+5V 20MHz OUT GND
0.1uF
OSCo No Connection
Figure 9 - Clock Oscillator Circuit For applications requiring 32ppm clock accuracy, the following clock oscillator module may be used.
CTS CXO-65-HG-5-C-20.0MHz Frequency: 20MHz Tolerance: 25ppm 0C to 70C
15
MT9044
Rise & Fall Time: Duty Cycle: 8ns (0.5V 4.5V 50pF) 45% to 55%
Advance Information
e.g., CTS R1027-2BB-20.0MHZ (20ppm absolute, 6ppm 0C to 50C, 32pF, 25)
The output clock should be connected directly (not AC coupled) to the OSCi input of the MT9044, and the OSCo output should be left open as shown in Figure 9. Crystal Oscillator - Alternatively, a Crystal Oscillator may be used. A complete oscillator circuit made up of a crystal, resistor and capacitors is shown in Figure 10.
MT9044 OSCi 20MHz 1M
Guard Time Adjustment Excessive switching of the timing reference (from PRI to SEC) in the MT9044 can be minimized by first entering Holdover Mode for a predetermined maximum time (i.e., guard time). If the degraded signal returns to normal before the expiry of the guard time (e.g. 2.5 seconds), then the MT9044 is returned to its Normal Mode (with no reference switch taking place). Otherwise, the reference input may be changed from Primary to Secondary.
MT9044 GTo R 150k
+
C 10uF
56pF OSCo 100
39pF
3-50pF
1uH GTi RP 1k
1uH inductor: may improve stability and is optional
Figure 10 - Crystal Oscillator Circuit The accuracy of a crystal oscillator depends on the crystal tolerance as well as the load capacitance tolerance. Typically, for a 20MHz crystal specified with a 32pF load capacitance, each 1pF change in load capacitance contributes approximately 9ppm to the frequency deviation. Consequently, capacitor tolerances, and stray capacitances have a major effect on the accuracy of the oscillator frequency. The trimmer capacitor shown in Figure 10 may be used to compensate for capacitive effects. If accuracy is not a concern, then the trimmer may be removed, the 39pF capacitor may be increased to 56pF, and a wider tolerance crystal may be substituted. The crystal should be a fundamental mode type - not an overtone. The fundamental mode crystal permits a simpler oscillator circuit with no additional filter components and is less likely to generate spurious responses. The crystal specification is as follows.
Frequency: Tolerance: Oscillation Mode: Resonance Mode: Load Capacitance: Maximum Series Resistance: Approximate Drive Level:
16
Figure 11 - Symmetrical Guard Time Circuit A simple way to control the guard time (using Automatic Control) is with an RC circuit as shown in Figure 11. Resistor RP is for protection only and limits the current flowing into the GTi pin during power down conditions. The guard time can be calculated as follows. V DD guard time = RC x ln --------------------------------- V DD - V SIH guard time RC x 0.6 example guard time 150k x 10u x 0.6 = 0.9s
* VSIH is the logic high going threshold level for the GTi Schmitt Trigger input, see DC Electrical Characteristics
20MHz As required Fundamental Parallel 32pF 35 1mW
In cases where fast toggling might be expected of the LOS1 input, then an unsymmetrical Guard Time Circuit is recommended. This ensures that reference switching doesn't occur until the full guard time value has expired. An unsymmetrical Guard Time Circuit is shown in Figure 12.
Advance Information
MT9044 GTo RC 150k
MT9044
For instance, 10 Normal to Holdover to Normal mode change sequences occur, and in each case Holdover was entered for 2s. Each mode change sequence could account for a phase change as large as 350ns. Thus, the accumulated phase change could be as large as 3.5us, and, the overall MTIE could be as large as 3.5us. Phase hold = 0.05 ppm x 2s = 100ns Phase state = 50ns + 200ns = 250ns
RP 1k
+
RD 1k GTi
C 10uF
Phase 10 = 10 x ( 250ns + 100ns ) = 3.5us
* * * 0.05ppm is the accuracy of Holdover Mode 50ns is the maximum phase continuity of the MT9044 from Normal Mode to Holdover Mode 200ns is the maximum phase continuity of the MT9044 from Holdover Mode to Normal Mode (with or without TIE Corrector Circuit)
Figure 12 - Unsymmetrical Guard Time Circuit Figure 13 shows a typical timing example of an unsymmetrical Guard Time Circuit with the MT9044 in Automatic Control. TIE Correction (using GTi) When Primary Holdover Mode is entered for short time periods, TIE correction should not be enabled. This will prevent unwanted accumulated phase change between the input and output. This is mainly applicable to Manual Control, since Automatic Control together with the Guard Time Circuit inherently operate in this manner.
When 10 Normal to Holdover to Normal mode change sequences occur without MTIE enabled, and in each case holdover was entered for 2s, each mode change sequence could still account for a phase change as large as 350ns. However, there would be no accumulated phase change, since the input to output phase is re-aligned after every Holdover to Normal state change. The overall MTIE would only be 350ns.
SEC SIGNAL STATUS LOS2 PRI SIGNAL STATUS
GOOD
GOOD
BAD TD
GOOD TD
BAD
GOOD
LOS1
GTo VSIH GTi
MT9044 STATE
PRI NORMAL
PRI HOLDOVER
PRI NORMAL
PRI HOLDOVER
SEC NORMAL
PRI NORMAL
NOTES: 1. TD represents the time delay from when the reference goes bad to when the MT9044 is provided with a LOS indication.
Figure 13 - Automatic Control, Unsymmetrical Guard Time Circuit Timing Example
17
MT9044
Reset Circuit A simple power up reset circuit with about a 50us reset low time is shown in Figure 14. Resistor RP is for protection only and limits current into the RST pin during power down conditions. The reset low time is not critical but should be greater than 300ns.
MT9044 +5V R 10k RST RP 1k C 10nF
Advance Information
Dual T1 Reference Sources with MT9044 in Automatic Control For systems requiring simple state machine control, the application circuit shown in Figure 15 using Automatic Control may be used. In this circuit, the MT9044 is operating Automatically, using a Guard Time Circuit, and the LOS1 and LOS2 inputs to determine all mode changes. Since the Guard Time Circuit is set to about 1s, all line interruptions (LOS1=1) less than 1s will cause the MT9044 to go from Primary Normal Mode to Holdover Mode and not switch references. For line interruptions greater than 1s, the MT9044 will switch Modes from Holdover to Secondary Normal, provided that the secondary signal is valid (LOS2=0). After receiving a good primary signal (LOS1=0), the MT9044 will switch back to Primary Normal Mode For complete Automatic Control state machine details, refer to Table 5 for the State Table, and Figure 8 for the State Diagram.
Figure 14 - Power-Up Reset Circuit
To Line 1 MT9074 TTIP To TX Line XFMR TRING F0i C4i DSTo DSTi
RTIP To RX Line XFMR RRING
MT9044 E1.5o LOS PRI SEC + 5V LOS1 LOS2 MS1 MS2 RSEL TRST 1k F0i C4i RST 10k 10nF CLOCK Out 20MHz 32ppm OSCi + 5V 10uF E1.5o LOS 1k + FS1 FS2 150k GTo GTi 1k F0o C4o + 5V
To Line 2
MT9074 TTIP DSTo DSTi
To TX Line XFMR
TRING
RTIP To RX Line XFMR RRING
MT8985 STo0 STi0 STo1 STi1 F0i C4i
Figure 15 - Dual T1 Reference Sources with MT9044 in 1.544MHz Automatic Control
18
Advance Information
MT9044
To Line 1 To TX Line XFMR
MT9075 TTIP TRING F0i C4i RxFP LOS MT9044 PRI SEC F0o C4o + 5V DSTo DSTi
RTIP To RX Line XFMR RRING
To Line 2
MT9075 TTIP DSTo DSTi
To TX Line XFMR
LOS1 C1.5o LOS2 FS1 MS1 FS2 MS2 RSEL GTi TRST RST OSCi
TRING RTIP F0i C4i RxFP LOS
CLOCK Out 20MHz 32ppm
To RX Line XFMR
RRING
External Stimulus CONTROLLER MT8985 STo0 STi0 STo1 STi1 F0i C4i
Figure 16 - Dual E1 Reference Sources with MT9044 in 8kHz Manual Control Dual E1 Reference Sources with MT9044 in Manual Control For systems requiring complex state machine control, the application circuit shown in Figure 16 using Manual Control may be used. In this circuit, the MT9044 is operating Manually and is using a controller for all mode changes. The controller sets the MT9044 modes (Normal, Holdover or Freerun) by controlling the MT9044 mode/control select pins (MS2 and MS1). The input (Primary or Secondary) is selected with the reference select pin (RSEL). TIE correction from Primary Holdover Mode to Primary Normal Mode is enabled and disabled with the guard time input pin (GTi). The input to output phase alignment is re-aligned with the TIE circuit reset pin (TCLR), and a complete device reset is done with the RST pin. The controller uses two stimulus inputs (LOS) directly from the MT9075 E1 interfaces, as well as an external stimulus input. The external input may come from a device that monitors the status registers of the E1 interfaces, and outputs a logic one in the event of an unacceptable status condition. For complete Manual Control state machine details, refer to Table 4 for the State Table, and Figure 7 for the State Diagram.
19
MT9044
Advance Information
To E1 Line To TX Line XFMR
MT9075 TTIP TRING F0i C4i RxFP LOS MT9044 PRI F0o C4o + 5V DSTo DSTi
RTIP To RX Line XFMR RRING
To OC3 Line To TX Line XFMR
MT90840 PDo0-7 STo0-7 STi0-7 PPFTo 1k
LOS1 C1.5o LOS2 FS1 MS1 FS2 MS2 RSEL OSCi TCLR C19o ACKi RST ACKo GTi 10k 10nF + 5V
CLOCK Out 20MHz 32ppm
PDi0-7 To RX Line XFMR PCKR PPFRi
F0i C4b PCKT
MT90820 STo0 STi0 STo1-8 STi1-8 F0i C4i
Figure 17 - Single Source - E1 to STS-3 with 8kHz Reference Single Reference Source E1 to STS-3 with 8 kHz Reference The device may operate in freerun mode or with a single reference source. The 8 kHz output from the MT9075 is sourced from the clock extracted from the E1 trunk. It becomes the reference for the PLL which then generates ST-BUS signals F0o, C4o and C2o to form the system backplane clock. The MT90840 connects to the system backplane, as well as to an OC3 link via an STS-3 Framer and optical link. The 19.44 Mhz clock required by the MT90840 is generated by the MT9044. In the event that the E1 link is broken, the LOS output of the MT9075 goes high placing the MT9044 in freerun mode.
20
Advance Information
Absolute Maximum Ratings* Parameter 1 2 3 4 5 Supply voltage Voltage on any pin Current on any pin Storage temperature PLCC package power dissipation
Voltages are with respect to ground (V SS) unless otherwise stated.
MT9044
Symbol VDD VPIN IPIN TST PPD
Min -0.3 -0.3
Max 7.0 VDD+0.3 20
Units V V mA C mW mW
-55
125 900
6 MQFP package power dissipation PPD 900 * Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Recommended Operating Conditions* - * Voltages are with respect to ground (VSS) unless otherwise stated.
Characteristics 1 2 Supply voltage Operating temperature Sym VDD TA Min 4.5 -40 Max 5.5 85 Units V C
DC Electrical Characteristics* - * Voltages are with respect to ground (VSS) unless otherwise stated.
Characteristics 1 2 3 4 5 6 7 8 9 10 11 12 Supply current with: OSCi = 0V OSCi = Clock TTL high-level input voltage TTL low-level input voltage CMOS high-level input voltage CMOS low-level input voltage Schmitt high-level input voltage Schmitt low-level input voltage Schmitt hysteresis voltage Input leakage current High-level output voltage Low-level output voltage Sym IDDS IDD VIH VIL VCIH VCIL VSIH VSIL VHYS IIL VOH VOL 0.4 -10 0.8VDD 0.2VDD +10 2.3 0.8 0.7VDD 0.3VDD 2.0 0.8 Min Max 10 90 Units mA mA V V V V V V V uA V V OSCi OSCi GTi, RST GTi, RST GTi, RST VI=VDD or 0V IOH=4mA IOL=4mA Conditions/Notes Outputs unloaded Outputs unloaded
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
21
MT9044
AC Electrical Characteristics - Performance
Characteristics 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Phase lock time Output phase continuity with: reference switch Capture range with OSCi at: Holdover Mode accuracy with OSCi at: Freerun Mode accuracy with OSCi at: 0ppm 32ppm 100ppm 0ppm 32ppm 100ppm 0ppm 32ppm 100ppm Sym Min -0 -32 -100 -0.05 -0.05 -0.05 -230 -198 -130 Max +0 +32 +100 +0.05 +0.05 +0.05 +230 +198 +130 30 200 200 200 50 600 45 8kHz -18k -36k -36k +18k +36k +36k
Advance Information
Units ppm ppm ppm ppm ppm ppm ppm ppm ppm s ns ns ns ns ns us/s ppm ppm ppm
Conditions/Notes 5-8 5-8 5-8 1,2,4,6-8,40 1,2,4,6-8,40 1,2,4,6-8,40 1-3,6-8 1-3,6-8 1-3,6-8 1-3,6-14 1-3,6-14 1-2,4-14 1-,4,6-14 1-3,6-14 1-14,27 1-14,27 1-3,6,9-11 1-3,7,9-11 1-3,8-11
mode switch to Normal mode switch to Freerun mode switch to Holdover MTIE (maximum time interval error) Output phase slope Reference input for Auto-Holdover with:
1.544MHz 2.048MHz
See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels* - Voltages are
with respect to ground (V SS) unless otherwise stated.
Characteristics 1 2 3 Threshold Voltage Rise and Fall Threshold Voltage High Rise and Fall Threshold Voltage Low
Sym VT VHM VLM
Schmitt 1.5 2.3 0.8
TTL 1.5 2.0 0.8
CMOS 0.5VDD 0.7VDD 0.3VDD
Units V V V
* Supply voltage and operating temperature are as per Recommended Operating Conditions. * Timing for input and output signals is based on the worst case result of the combination of TTL and CMOS thresholds. * See Figure 18.
Timing Reference Points ALL SIGNALS tIRF, tORF tIRF, tORF V HM VT VLM
Figure 18 - Timing Parameter Measurement Voltage Levels
22
Advance Information
AC Electrical Characteristics - Input/Output Timing
Characteristics 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Reference input pulse width high or low Reference input rise or fall time 8kHz reference input to F8o delay 1.544MHz reference input to F8o delay 2.048MHz reference input to F8o delay F8o to F0o delay F16o setup to C16o falling F16o hold from C16o rising F8o to C1.5o delay F8o to C6o delay F8o to C3o delay F8o to C2o delay F8o to C4o delay F8o to C8o delay F8o to C16o delay F8o to TSP delay F8o to RSP delay F8o to C19o delay C1.5o pulse width high or low C3o pulse width high or low C6o pulse width high or low C2o pulse width high or low C4o pulse width high or low C8o pulse width high or low C16o pulse width high or low TSP pulse width high RSP pulse width high C19o pulse width high or low F0o pulse width low F8o pulse width high F16o pulse width low Output clock and frame pulse rise or fall time Input Controls Setup Time Input Controls Hold Time Sym tRW tIRF tR8D tR15D tR2D tF0D tF16S tF16H tC15D tC6D tC3D tC2D tC4D tC8D tC16D tTSPD tRSPD tC19D tC15W tC3W tC6W tC2W tC4W tC8W tC16WL tTSPW tRSPW tC19W tF0WL tF8WH tF16WL tORF tS tH 100 100 -21 337 222 110 11 0 -51 -3 -51 -13 -13 -13 -13 -10 -10 0 309 149 72 230 111 52 24 478 474 16 230 111 52 Min 100
MT9044
Max
Units ns
10 6 363 238 134 35 20 -37 11 -37 2 2 2 2 10 10 52 339 175 86 258 133 70 35 494 491 36 258 133 70 9
ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns
See "Notes" following AC Electrical Characteristics tables.
23
MT9044
Advance Information
tR8D PRI/SEC 8kHz tR15D PRI/SEC 1.544MHz tR2D PRI/SEC 2.048MHz tRW tRW VT tRW VT VT
F8o NOTES: 1. Input to output delay values are valid after a TRST or RST with no further state changes
VT
Figure 19 - Input to Output Timing (Normal Mode)
tF8WH F8o tF0WL F0o tF16WL F16o tC16WL C16o tC8W C8o tC4W C4o tC2W C2o tC6W C6o tC3W C3o tC15W C1.5o tC19W C19o tC19W tC19D VT tC15D VT tC3W tC3D VT tC6W tC6D tC2D VT tC4W tC4D VT tC8W tC8D VT VT tF16S tF16H tF0D VT VT
tC16D
VT
VT
Figure 20 - Output Timing 1
24
Advance Information
MT9044
F8o
VT
C2o
VT
tRSPD
RSP tTSPW TSP tTSPD tRSPW VT VT
Figure - 21 Output Timing 2
F8o tS MS1,2 LOS1,2 RSEL, GTi tH
VT
VT
Figure 22 - Input Controls Setup and Hold Timing
AC Electrical Characteristics - Intrinsic Jitter Unfiltered
Characteristics 1 2 3 4 5 6 7 8 9 10 11 12 13 Intrinsic jitter at F8o (8kHz) Intrinsic jitter at F0o (8kHz) Intrinsic jitter at F16o (8kHz) Intrinsic jitter at C1.5o (1.544MHz) Intrinsic jitter at C2o (2.048MHz) Intrinsic jitter at C3o (3.088MHz) Intrinsic jitter at C6o (6.312MHz) Intrinsic jitter at C4o (4.096MHz) Intrinsic jitter at C8o (8.192MHz) Intrinsic jitter at C16o (16.384MHz) Intrinsic jitter at TSP (8kHz) Intrinsic jitter at RSP (8kHz) Intrinsic jitter at C19o (19.44MHz) Sym Min Max 0.0002 0.0002 0.0002 0.030 0.040 0.060 0.120 0.080 0.160 0.320 0.0002 0.0002 0.10 Units UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp Conditions/Notes 1-14,21-24,28 1-14,21-24,28 1-14,21-24,28 1-14,21-24,29 1-14,21-24,30 1-14,21-24,31 1-14,21-24,31 1-14,21-24,32 1-14,21-24,33 1-14,21-24,34 1-14,21-24,28 1-14,21-24,28 1-14,21-24,41
See "Notes" following AC Electrical Characteristics tables.
25
MT9044
Advance Information
AC Electrical Characteristics - C1.5o (1.544MHz) Intrinsic Jitter Filtered
Characteristics 1 2 3 4 Intrinsic jitter (4Hz to 100kHz filter) Intrinsic jitter (10Hz to 40kHz filter) Intrinsic jitter (8kHz to 40kHz filter) Intrinsic jitter (10Hz to 8kHz filter) Sym Min Max 0.015 0.010 0.010 0.005 Units UIpp UIpp UIpp UIpp Conditions/Notes 1-14,21-24,29 1-14,21-24,29 1-14,21-24,29 1-14,21-24,29
See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - C2o (2.048MHz) Intrinsic Jitter Filtered
Characteristics 1 2 3 4 Intrinsic jitter (4Hz to 100kHz filter) Intrinsic jitter (10Hz to 40kHz filter) Intrinsic jitter (8kHz to 40kHz filter) Intrinsic jitter (10Hz to 8kHz filter) Sym Min Max 0.015 0.010 0.010 0.005 Units UIpp UIpp UIpp UIpp Conditions/Notes 1-14,21-24,30 1-14,21-24,30 1-14,21-24,30 1-14,21-24,30
See "Notes" following AC Electrical Characteristics tables
AC Electrical Characteristics - 8kHz Input to 8kHz Output Jitter Transfer
Characteristics 1 2 3 4 5 6 Jitter attenuation for 1Hz@0.01UIpp input Jitter attenuation for 1Hz@0.54UIpp input Jitter attenuation for 10Hz@0.10UIpp input Jitter attenuation for 60Hz@0.10UIpp input Jitter attenuation for 300Hz@0.10UIpp input Jitter attenuation for 3600Hz@0.005UIpp input Sym Min 0 6 12 28 42 45 Max 6 16 22 38 Units dB dB dB dB dB dB Conditions/Notes 1-3,6,9-14,21-22,24,28,35 1-3,6,9-14,21-22,24,28,35 1-3,6,9-14,21-22,24,28,35 1-3,6,9-14,21-22,24,28,35 1-3,6,9-14,21-22,24,28,35 1-3,6,9-14,21-22,24,28,35
See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - 1.544MHz Input to 1.544MHz Output Jitter Transfer
Characteristics 1 2 3 4 5 6 7 Jitter attenuation for 1Hz@20UIpp input Jitter attenuation for 1Hz@104UIpp input Jitter attenuation for 10Hz@20UIpp input Jitter attenuation for 60Hz@20UIpp input Jitter attenuation for 300Hz@20UIpp input Jitter attenuation for 10kHz@0.3UIpp input Jitter attenuation for 100kHz@0.3UIpp input Sym Min 0 6 12 28 42 45 45 Max 6 16 22 38 Units dB dB dB dB dB dB dB Conditions/Notes 1-3,7,9-14,21-22,24,29,35 1-3,7,9-14,21-22,24,29,35 1-3,7,9-14,21-22,24,29,35 1-3,7,9-14,21-22,24,29,35 1-3,7,9-14,21-22,24,29,35 1-3,7,9-14,21-22,24,29,35 1-3,7,9-14,21-22,24,29,35
See "Notes" following AC Electrical Characteristics tables.
26
Advance Information
MT9044
AC Electrical Characteristics - 2.048MHz Input to 2.048 MHz Output Jitter Transfer
Characteristics 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Jitter at output for 1Hz@3.00UIpp input with 40Hz to 100kHz filter Jitter at output for 3Hz@2.33UIpp input with 40Hz to 100kHz filter Jitter at output for 5Hz@2.07UIpp input with 40Hz to 100kHz filter Jitter at output for 10Hz@1.76UIpp input with 40Hz to 100kHz filter Jitter at output for 100Hz@1.50UIpp input with 40Hz to 100kHz filter Jitter at output for 2400Hz@1.50UIpp input with 40Hz to 100kHz filter Jitter at output for 100kHz@0.20UIpp input with 40Hz to 100kHz filter Sym Min Max 2.9 0.09 1.3 0.10 0.80 0.10 0.40 0.10 0.06 0.05 0.04 0.03 0.04 0.02 Units UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp Conditions/Notes 1-3,8,9-14,21-22,24,30,35 1-3,8,9-14,21-22,24,30,36 1-3,8,9-14,21-22,24,30,35 1-3,8,9-14,21-22,24,30,36 1-3,8,9-14,21-22,24,30,35 1-3,8,9-14,21-22,24,30,36 1-3,8,9-14,21-22,24,30,35 1-3,8,9-14,21-22,24,30,36 1-3,8,9-14,21-22,24,30,35 1-3,8,9-14,21-22,24,30,36 1-3,8,9-14,21-22,24,30,35 1-3,8,9-14,21-22,24,30,36 1-3,8,9-14,21-22,24,30,35 1-3,8,9-14,21-22,24,30,36
See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - 8kHz Input Jitter Tolerance
Characteristics 1 2 3 4 5 6 7 8 Jitter tolerance for 1Hz input Jitter tolerance for 5Hz input Jitter tolerance for 20Hz input Jitter tolerance for 300Hz input Jitter tolerance for 400Hz input Jitter tolerance for 700Hz input Jitter tolerance for 2400Hz input Jitter tolerance for 3600Hz input Sym Min 0.80 0.70 0.60 0.20 0.15 0.08 0.02 0.01 Max Units UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp Conditions/Notes 1-3,6,9-14,21-22,24-26,28 1-3,6,9-14,21-22,24-26,28 1-3,6,9-14,21-22,24-26,28 1-3,6,9-14,21-22,24-26,28 1-3,6,9-14,21-22,24-26,28 1-3,6,9-14,21-22,24-26,28 1-3,6,9-14,21-22,24-26,28 1-3,6,9-14,21-22,24-26,28
See "Notes" following AC Electrical Characteristics tables.
27
MT9044
AC Electrical Characteristics - 1.544MHz Input Jitter Tolerance
Characteristics 1 2 3 4 5 6 7 8 9 Jitter tolerance for 1Hz input Jitter tolerance for 5Hz input Jitter tolerance for 20Hz input Jitter tolerance for 300Hz input Jitter tolerance for 400Hz input Jitter tolerance for 700Hz input Jitter tolerance for 2400Hz input Jitter tolerance for 10kHz input Jitter tolerance for 100kHz input Sym Min 150 140 130 35 25 15 4 1 0.5 Max Units UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp
Advance Information
Conditions/Notes 1-3,7,9-14,21-22,24-26,29 1-3,7,9-14,21-22,24-26,29 1-3,7,9-14,21-22,24-26,29 1-3,7,9-14,21-22,24-26,29 1-3,7,9-14,21-22,24-26,29 1-3,7,9-14,21-22,24-26,29 1-3,7,9-14,21-22,24-26,29 1-3,7,9-14,21-22,24-26,29 1-3,7,9-14,21-22,24-26,29
See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - 2.048MHz Input Jitter Tolerance
Characteristics 1 2 3 4 5 6 7 8 9 Jitter tolerance for 1Hz input Jitter tolerance for 5Hz input Jitter tolerance for 20Hz input Jitter tolerance for 300Hz input Jitter tolerance for 400Hz input Jitter tolerance for 700Hz input Jitter tolerance for 2400Hz input Jitter tolerance for 10kHz input Jitter tolerance for 100kHz input Sym Min 150 140 130 50 40 20 5 1 1 Max Units UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp UIpp Conditions/Notes 1-3,8,9-14,21-22,24-26,30 1-3,8,9-14,21-22,24-26,30 1-3,8,9-14,21-22,24-26,30 1-3,8,9-14,21-22,24-26,30 1-3,8,9-14,21-22,24-26,30 1-3,8,9-14,21-22,24-26,30 1-3,8,9-14,21-22,24-26,30 1-3,8,9-14,21-22,24-26,30 1-3,8,9-14,21-22,24-26,30
See "Notes" following AC Electrical Characteristics tables.
AC Electrical Characteristics - OSCi 20MHz Master Clock Input
Characteristics 1 2 3 4 5 6 Duty cycle Rise time Fall time Frequency accuracy (20 MHz nominal) Sym Min -0 -32 -100 40 Max +0 +32 +100 60 10 10 Units ppm ppm ppm % ns ns Conditions/Notes 15,18 16,19 17,20
See "Notes" following AC Electrical Characteristics tables.
28
Advance Information
Notes:
Voltages are with respect to ground (VSS) unless otherwise stated. Supply voltage and operating temperature are as per Recommended Operating Conditions. Timing parameters are as per AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels 1. PRI reference input selected. 2. SEC reference input selected. 3. Normal Mode selected. 4. Holdover Mode selected. 5. Freerun Mode selected. 6. 8kHz Frequency Mode selected. 7. 1.544MHz Frequency Mode selected. 8. 2.048MHz Frequency Mode selected. 9. Master clock input OSCi at 20MHz 0ppm. 10. Master clock input OSCi at 20MHz 32ppm. 11. Master clock input OSCi at 20MHz 100ppm. 12. Selected reference input at 0ppm. 13. Selected reference input at 32ppm. 14. Selected reference input at 100ppm. 15. For Freerun Mode of 0ppm. 16. For Freerun Mode of 32ppm. 17. For Freerun Mode of 100ppm. 18. For capture range of 230ppm. 19. For capture range of 198ppm. 20. For capture range of 130ppm. 21. 25pF capacitive load. 22. OSCi Master Clock jitter is less than 2nspp, or 0.04UIpp where1UIpp=1/20MHz. 23. Jitter on reference input is less than 7nspp. 24. Applied jitter is sinusoidal. 25. Minimum applied input jitter magnitude to regain synchronization. 26. Loss of synchronization is obtained at slightly higher input jitter amplitudes. 27. Within 10ms of the state, reference or input change. 28. 1UIpp = 125us for 8kHz signals. 29. 1UIpp = 648ns for 1.544MHz signals. 30. 1UIpp = 488ns for 2.048MHz signals. 31. 1UIpp = 323ns for 3.088MHz signals. 32. 1UIpp = 244ns for 4.096MHz signals. 33. 1UIpp = 122ns for 8.192MHz signals. 34. 1UIpp = 61ns for 16.384MHz signals. 35. No filter. 36. 40Hz to 100kHz bandpass filter. 37. With respect to reference input signal frequency. 38. After a RST or TRST. 39. Master clock duty cycle 40% to 60%. 40. Prior to Holdover Mode, device was in Normal Mode and phase locked. 41. 1Ulpp = 51ns for 19.44MHz signals.
MT9044
29
http://www.mitelsemi.com
World Headquarters - Canada Tel: +1 (613) 592 2122 Fax: +1 (613) 592 6909 North America Tel: +1 (770) 486 0194 Fax: +1 (770) 631 8213 Asia/Pacific Tel: +65 333 6193 Fax: +65 333 6192 Europe, Middle East, and Africa (EMEA) Tel: +44 (0) 1793 518528 Fax: +44 (0) 1793 518581
Information relating to products and services furnished herein by Mitel Corporation or its subsidiaries (collectively "Mitel") is believed to be reliable. However, Mitel assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Mitel or licensed from third parties by Mitel, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Mitel, or non-Mitel furnished goods or services may infringe patents or other intellectual property rights owned by Mitel. This publication is issued to provide information only and (unless agreed by Mitel in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Mitel without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user's responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Mitel's conditions of sale which are available on request.
M Mitel (design) and ST-BUS are registered trademarks of MITEL Corporation Mitel Semiconductor is an ISO 9001 Registered Company Copyright 1999 MITEL Corporation All Rights Reserved Printed in CANADA TECHNICAL DOCUMENTATION - NOT FOR RESALE


▲Up To Search▲   

 
Price & Availability of MT9044AL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X